brand,model,btu,volts,amps_cool,cab_w,cab_h,cab_d,cab_source,min_w,max_w,min_h,circuit,receptacle,extension_cord,source,checked,note Frigidaire,FHWW063WB,6000,115,4.7,18.5,13,15.5,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW063WB_EN.pdf,24,36,14,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW063WB_EN.pdf,2026-10-17, Frigidaire,FHWW083WB,8000,115,6.4,18.5,13,15.5,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW083WB_EN.pdf,24,36,14,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW083WB_EN.pdf,2026-10-17, Frigidaire,FHWW103WB,10000,115,8,19,14.5,21.5,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW103WB_EN.pdf,25,36,15.5,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW103WB_EN.pdf,2026-10-17, Frigidaire,FHWW123WB,12000,115,9.7,19,14.5,21.5,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW123WB_EN.pdf,25,36,15.5,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW123WB_EN.pdf,2026-10-17, Frigidaire,FHWW153WB,15100,115,9.4,24,18,25,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW153WB_EN.pdf,28,40.5,18.5,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/FHWW153WB_EN.pdf,2026-10-17, Frigidaire Gallery,GHWQ083WC,8000,115,8.8,19.5,14,23,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/GHWQ083WC_EN.pdf,24,38.8,14,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/GHWQ083WC_EN.pdf,2026-10-17, Frigidaire Gallery,GHWQ123WC,12000,115,12.2,19.5,14,23,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/GHWQ123WC_EN.pdf,24,38.8,14,,,,https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Product%20Specifications%20Sheet/English/GHWQ123WC_EN.pdf,2026-10-17, LG,LW8016ER,8000,115,6.2,,,,,,,,,,,https://www.lg.com/us/support/products/documents/LW8016ER%20Spec%20Sheet.pdf,2026-10-17, LG,LW1216ER,12000,115,9.3,,,,,,,,,,,https://www.lg.com/us/support/products/documents/LW1216ER%20Spec%20Sheet.pdf,2026-10-17, Friedrich,CCW15B10B,15000,115,,23.625,17.875,25.375,https://www.friedrich.com/hubfs/2023%20Literature%20PDFs/Installation%20Manuals/2023%20Chill%20Premier%20CCW%20R-32%2015-24K%20IOM.pdf,28,41,20,Single outlet circuit only; 15 A circuit or time delay fuse,"NEMA 5-15R (15 A, 125 V)",Do not use,https://www.friedrich.com/hubfs/2023%20Literature%20PDFs/Installation%20Manuals/2023%20Chill%20Premier%20CCW%20R-32%2015-24K%20IOM.pdf,2026-10-17,"Friedrich gives the circuit rating, not the running amps. Minimum height is the vertical clearance in the manual." Friedrich,CCW18B30B,18000,230,,23.625,17.875,25.375,https://www.friedrich.com/hubfs/2023%20Literature%20PDFs/Installation%20Manuals/2023%20Chill%20Premier%20CCW%20R-32%2015-24K%20IOM.pdf,28,41,20,Single outlet circuit only; 20 A circuit or time delay fuse,"NEMA 6-20R (20 A, 250 V)",Do not use,https://www.friedrich.com/hubfs/2023%20Literature%20PDFs/Installation%20Manuals/2023%20Chill%20Premier%20CCW%20R-32%2015-24K%20IOM.pdf,2026-10-17,"Friedrich gives the circuit rating, not the running amps." Friedrich,CCW24B30B,24000,230,,26.375,18.75,26.875,https://www.friedrich.com/hubfs/2023%20Literature%20PDFs/Installation%20Manuals/2023%20Chill%20Premier%20CCW%20R-32%2015-24K%20IOM.pdf,30,41,21,Single outlet circuit only; 20 A circuit or time delay fuse,"NEMA 6-20R (20 A, 250 V)",Do not use,https://www.friedrich.com/hubfs/2023%20Literature%20PDFs/Installation%20Manuals/2023%20Chill%20Premier%20CCW%20R-32%2015-24K%20IOM.pdf,2026-10-17,"Friedrich gives the circuit rating, not the running amps." Midea,MAW08V1QWT (U),8000,115,,19.2,13.5,22.0,https://data.energystar.gov/resource/5xn2-dv4h.json?pd_id=4429367,22,36,13.75,Do not share the outlet with other appliances,"Grounded wall receptacle, time delay fuse or circuit breaker",Do not use,https://www.midea.com/content/dam/midea-aem/us/heating-and-cooling/maw08v1qwt-t/r-MAW08V1QWT-T.pdf,2026-10-17, Midea,MAW10RV1CWT / MAW12RV1CWT / MAW14RV1CWT,,115,,,,,,23,36,,Always install a circuit breaker and a dedicated power circuit,"Grounded wall receptacle, time delay fuse or circuit breaker",Do not use,https://www.midea.com/content/dam/midea-aem/us/air-conditioners/window-a-c/maw10rv1cwt/InverterPlus-10k-12k-14k-Manual.pdf,2026-10-17,"One manual for the 10,000, 12,000 and 14,000 Btu models." TCL,"5,000 Btu (T05WV9M)",5000,115,,16.0,12.5,15.5,https://data.energystar.gov/resource/5xn2-dv4h.json?pd_id=4514539,23,36,14.5,,,,https://tcl.helpjuice.com/109363-common-questions/what-size-window-do-i-need-236,2026-10-17, TCL,"8,000 Btu (T08WV9S)",8000,115,,18.6,13.3,17.7,https://data.energystar.gov/resource/5xn2-dv4h.json?pd_id=4514532,23,36,14.5,,,,https://tcl.helpjuice.com/109363-common-questions/what-size-window-do-i-need-236,2026-10-17, TCL,"10,000 Btu (T10WV9S)",10000,115,,19.8,15.2,21.5,https://data.energystar.gov/resource/5xn2-dv4h.json?pd_id=4514547,26,36,16,,,,https://tcl.helpjuice.com/109363-common-questions/what-size-window-do-i-need-236,2026-10-17, GE Profile,AHTR10AC,10100,115,,20.52,13.91,19.89,https://www.geappliances.com/appliance/GE-Profile-ENERGY-STAR-10-100-BTU-Inverter-Smart-Ultra-Quiet-Window-Air-Conditioner-for-Medium-Rooms-up-to-450-sq-ft-AHTR10AC,26.375,40.5,14.0625,,,,https://www.geappliances.com/appliance/GE-Profile-ENERGY-STAR-10-100-BTU-Inverter-Smart-Ultra-Quiet-Window-Air-Conditioner-for-Medium-Rooms-up-to-450-sq-ft-AHTR10AC,2026-10-17,GE product page read in a browser on 17 Oct 2026; Btu and volts from ENERGY STAR (AHTR10ACH2)